• Login
    View Item 
    •   AFRUIR Home
    • School of Humanities, Arts and Social Sciences.
    • Health science
    • Research Articles
    • View Item
    •   AFRUIR Home
    • School of Humanities, Arts and Social Sciences.
    • Health science
    • Research Articles
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Sputum quality and diagnostic performance of GeneXpert MTB/RIF among smear-negative adults with presumed tuberculosis in Uganda

    Thumbnail
    View/Open
    Main article (1.344Mb)
    Date
    2017
    Author
    Meyer, J. Amanda
    Atuheire, Collins
    Worodria, William
    Kizito, Samuel
    Katamba, Achilles
    Sanyu, Ingvar
    Andama, Alfred
    Ayakaka, Irene
    Cattamanchi, Adithya
    Bwanga, Freddie
    Huang, Laurence
    Davis, J. Lucian
    Metadata
    Show full item record
    Abstract
    Background Introduction of GeneXpert MTB/RIF (Xpert) assay has constituted a major breakthrough for tuberculosis (TB) diagnostics. Several patient factors may influence diagnostic performance of Xpert including sputum quality. Objective We carried out a prospective, observational, cross-sectional study to determine the effect of sputum quality on diagnostic performance of Xpert among presumed TB patients in Uganda. Methods We collected clinical and demographic information and two sputum samples from participants. Staff recorded sputum quality and performed LED fluorescence microscopy and mycobacterial culture on each sample. If both smear examinations were negative, Xpert testing was performed. We calculated diagnostic yield, sensitivity, specificity, and other indicators for Xpert for each stratum of sputum quality in reference to a standard of mycobacterial culture. Results Patients with salivary sputum showed a trend towards a substantially higher proportion of samples that were Xpert-positive (54/286, 19%, 95% CI 15–24) compared with those with all other sputum sample types (221/1496, 15%, 95% CI 13–17). Blood-stained sputum produced the lowest sensitivity (28%; 95% CI 12–49) and salivary sputum the highest (66%; 95% CI 53–77). Specificity didn’t vary meaningfully by sample types. Salivary sputum was significantly more sensitive than mucoid sputum (+13%, 95% CI +1 to +26), while blood-stained sputum was significantly less sensitive (-24%, 95% CI -42 to -5). Conclusions Our findings demonstrate the need to exercise caution in collecting sputum for Xpert and in interpreting results because sputum quality may impact test yield and sensitivity. In particular, it may be wise to pursue additional testing should blood-stained sputum test negative while salivary sputum should be readily accepted for Xpert testing given its higher sensitivity and potentially higher yield than other sample types. These findings challenge conventional recommendations against collecting salivary sputum for TB diagnosis and could inform new standards for sputum quality.
    URI
    https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0180572
    Collections
    • Research Articles [5]

    AFRU-IR
    Contact Us | Send Feedback
    African Bible University
     

     

    Browse

    All of AFRUIRCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    AFRU-IR
    Contact Us | Send Feedback
    African Bible University